S009

Beam splice with bolted endplates. Optinal T-Stub stiffener. No backplates.

Profile H L U Pipes Tubes
Beam 1
Beam 2

H and U beams allowed, but can't do a splice between H and U (combine).

Beam Position Criteria:

Plane Criteria
Both beams will be top aligned.
"s" gets the distance from beam top to plate top. This top-to-top distance is 20 mm by default.
H H beams will be web-to-web aligned taking the web center as reference.
U U beams will be web-to-web aligned taking the exterior face as reference.

Joint schema

Same beams

Joint schema

Different beams

Stiffener:

Case Stiffener
Beam 1 = Beam 2 No stiffener
Two beams with a heigh difference `< 50 mm` No stiffener
No bolts below the beams No stiffener
Two beams with a heigh difference `>= 50 mm` and a bolt row below the small beam Auto stiffener. Thickness must be provided.

Parameters:

Field Use
s Vertical displacement between beams-top and endplate-top.

Related Common Parameters:

Back