S008

Column splice with cover plates. Only external flange cover plates. Web cover plates one or both sides.

Profile displacements: This connection assumes that the axes of the columns are aligned in case of "H". Case "U", profile webs must be aligned.

Joint schema

Connection drawing

Profile H L U Pipes Tubes
Bottom Column (1)
Top Column (2)

Parameters:

This sheet shows a cover plate selector. Plates are selected through 5 checkboxes.

Chackbox name Use
Flange Flange cover plates.
Fl autowidth If checked, flange cover plate width fitted to the profile flange.
Else, the width is calculated from e1, p1 and e1*.
Please note that neither top and bottom column can be "Any".
Web Web cover plate.
W autowidth If checked, web cover plate width fitted to web-to-radius intersection.
Else, the width is calculated from e1, p1 and e1*.
Please note that neither top and bottom column can be "Any".
W both Web cover plates in both sides.

Related Common Parameters:

Back